telos ABIC 2 Analyser
The PJF7992A (also referred to as ABIC 2) is base station IC manufactured by NXP Semiconductors targeted for the automotive market. It utilizes a single wire LIN connection for communication. The protocol of the ABIC 2 requires some special handling of LIN signals and commands which is not supported by most LIN bus analysers on the market. The telos ABIC 2 Analyser was designed to seamlessly integrate with the device and to support all standard and special protocol functions.
Product
- Connects to a host PC via USB
- Connects to the LIN bus via single wire LIN interface
- No extra power supply required
- Monitors communication with the ABIC2 on the LIN bus; besides standard LIN operations the ABIC2 special mode Buffered Communication is supported
- Extra test pins available for additional digital signal monitoring.
- Solid plastic housing with a standard DSUB-15 connector for all relevant signals
- Limitations: The special mode Transparent Transponder Communication is not supported
Software
- Displays Messages in both, raw data and interpreted format
- Ability to store an arbitrary number of messages to disk for later evaluation
- Host software runs under Windows XP, Vista and 7 on 32 and 64 bit platforms
- Automatic firmware update feature
- The software can be downloaded here
Connector
- Solid plastic housing with a standard DSUB-15 connector for all relevant signals
- Extra test pins available for additional digital signal monitoring

1: NC 9: LIN
2: GPIO 5 10: VCC Out 3.3V @ 100mA
3: GPIO 6 11: GPIO 4
4: NC 12: GPIO 3
5: NC 13: GPIO 2
6: NC 14: GPIO 1
7: GND 15: VCC In (GPIO)
8: VCC In (LIN) / ADC 3
The following pinning has been used for boards sold until august 2011 (serial numbers: 1BE5, 70B1, AAAC, 32CD, 2C64, 1B29, 0705, 7CC2, 352C, 5C71, 0FD9, 6107):
1: NC 9: ADC 3
2: NC 10: VCC Out 3.3V @ 100mA
3: GPIO 6 11: GPIO 4
4: NC 12: GPIO 3
5: VCC In (LIN) 13: GPIO 2
6: LIN 14: GPIO 1
7: GND 15: VCC In (GPIO)
8: GPIO 5
Deliverables
The telos ABIC 2 Analyser is delivered by standard mail/Fedex/TNT/UPS.
Everything is provided online; please install the software from this location.
This page serves as your manual. Please come back to us in case you are missing something.
Additionally, you need a standard USB cable and a DSUB 15 connector.